<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-23 22-19-36
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
95.60 MHz 4/5, 32 dBuV COURTOIS
Pilot RDS Phase Difference
0.0 kHz 3.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 13 kHz 5352 0,0747
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
2,5 dBr 2,89 dBr 3,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"COURTOIS" F228 0 (No PTY) 0 0 1 1 22:17, 23.03.2025
RT
-
AF EON
95.6, 101.1, 104.5 MHz -
FM Scope Station: 95.60 MHz, signal: 4/5 (32 dBuV) Max at: 13 kHz MIN: 11 kHz % above 76 kHz: 0,0747 Acquired: 2025/03/23 22:18:33 Total samples: 5352 Equivalent time: 0:04:27 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150